IC DRIVABLE PC BOARD RELAY FOR FIELD LOAD SWITCHING FEATURES
* Sealed to meet the combination process of automatic wave soldering and cleaning needs * Latching types available
ST-RELAYS
* High switching capacity and high sensitivity in subminiature size 150 mW pick-up, 8 A inrush capacity: 51 A for 1a1b, 35 A for 2a * High shock and vibration resistance Shock: 20 G, Vibration: 10 to 55 Hz at double amplitude of 2 mm
31 1.220
14 .551 11.3 .445
mm inch
SPECIFICATIONS
Contacts
Arrangement Contact material Initial contact resistance, max. Max. switching power Rating Max. switching voltage (resistive) Max. switching current HP rating Inrush current capability Mechanical (at 180 cpm) 8 A 250 V AC (resistive) Expected 5 A 30 V DC (resistive) life (min. operations) Electrical 3 A 100 V AC (lamp) 1 A 100 V AC (lamp) 1 Form A 2 Form A 1 Form B Gold flash over silver alloy 30 m 2,000 VA, 150 W 380 V AC, 30 V DC 8A 1/4 HP 125, 250 V AC 51 A (TV-3 equivalence) for 1a1b 35 A (TV-1 equivalence) for 2a 107 105 2 x 105 3 x 104 -- -- 3 x 104 Approx. 240 mW Approx. 240 mW
Characteristics (at 25C 77F 50% Relative humidity)
Max. operating speed Initial insulation resistance*1 Between contact sets Initial 20 cpm (at rated load) 1,000 M (at 500 V DC) 2,000 Vrms 1,200 Vrms 3,750 Vrms Min. 6,000 V Max. 15 ms (Approx. 10 ms) Max. 10 ms (Approx. 8 ms) Max. 10 ms (Approx. 8 ms) Max. 10 ms (Approx. 8 ms) Max. 55C with nominal coil voltage and at 8 A switching current Min. 196 m/s2 {20 G} Min. 980 m/s2 {100 G} 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2 mm 176.4 m/s2 {18 G}, 10 to 55 Hz at double amplitude of 3 mm -40C to +60C -40Fto +140F 5 to 85% R.H. Approx. 10g .353 oz
Coil (polarized) (at 25C 77F)
Single side stable Latching Remarks
* Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10 mA *3 Wave is standard shock voltage of 1.2 x 50s according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 11ms; detection time: 10s *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10s *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61).
Nominal operating power Nominal set and reset power
Between open contacts Between contacts and coil Surge voltage between coil and contact*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Set time*4 (latching) (at nominal voltage) Reset time*4 (latching) (at nominal voltage) Temperature rise (at 60C) Functional*5 Shock resistance Destructive*6
breakdown voltage*2 Vibration resistance Functional*7 Destructive
Conditions for operation, Ambient transport and storage*8 temp. (Not freezing and condensHumidity ing at low temperature)
Unit weight
TYPICAL APPLICATIONS
Sequence controllers, facsimiles, telephone controls, remote control security devices and security equipment.
ORDERING INFORMATION
Ex. ST 1 L2 DC48V
Contact arrangement 1: 1 Form A 1 Form B 2: 2 Form A
Operating function Nil: Single side stable L2: 2 coil latching
Coil voltage DC 3, 5, 6, 9, 12, 24, 48 V
(Note) Standard packing: Carton; 50 pcs., Case; 500 pcs.
249
ST
TYPES AND COIL DATA (at 20C 68F)
Single side stable
Part No. 1 Form A 2 Form A 1 Form B ST1-DC3V ST2-DC3V ST1-DC5V ST2-DC5V ST1-DC6V ST2-DC6V ST1-DC9V ST2-DC9V ST1-DC12V ST2-DC12V ST1-DC24V ST2-DC24V ST1-DC48V ST2-DC48V Nominal voltage, V DC 3 5 6 9 12 24 48 Pick-up voltage, V DC (max.) 2.4 4.0 4.8 7.2 9.6 19.2 38.4 Drop-out voltage, V DC (min.) 0.3 0.5 0.6 0.9 1.2 2.4 4.8 Maximum allowable voltage, V DC (60C 140F) 4.5 7.5 9.0 13.5 18.0 36.0 72.0 Coil resistance, (10%) 38 105 150 360 600 2,400 9,000 Nominal operating current, mA 75 47 40 25 20 10 4.7
2 coil latching
Part No. 1 Form A 2 Form A 1 Form B ST1-L2-DC3V ST2-L2-DC3V ST1-L2-DC5V ST2-L2-DC5V ST1-L2-DC6V ST2-L2-DC6V ST1-L2-DC9V ST2-L2-DC9V ST1-L2-DC12V ST2-L2-DC12V ST1-L2-DC24V ST2-L2-DC24V ST1-L2-DC48V ST2-L2-DC48V Nominal voltage, V DC 3 5 6 9 12 24 48 Set and reset voltage, V DC (max.) 2.4 4.0 4.8 7.2 9.6 19.2 38.4 Maximum allowable voltage, V DC (60C 140F) 4.5 7.5 9.0 13.5 18.0 36.0 72.0 Coil resistance, (10%) 40 110 155 360 640 2,400 10,200 Nominal operating current, mA 75 47 37.5 25 18.8 9.8 4.7 mm inch
14 .551
DIMENSIONS
31.0 1.220
PC board pattern (Copper-side view)
2 coil latching types only. 1
11.0 .433 0.3 .012 3.5 .138 7.62 .300 10.16 .400 7.62 .300 10.16 .400
Schematic (Bottom view) Single side stable 1a1b 2a
- + 4 1 - + 4
8 2.54 .100
7
6
5
8
7
6
5
(Deenergized condition) 2 coil latching 1a1b
1 -+ 2 3 +- 4 1 -+ 2
1 8
2 76
3
4 5
8-DIA. 1.4 .055
2.54 .100
2a
3 +- 4
Tolerance: 0.1 .004 General tolerance: 0.2 .008
8
7
6
5
8
7
6
5
(Reset condition)
Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts. Diagram shows the "reset" position when terminals 3 and 4 are energized. Energize terminals 1 and 2 to transfer contacts.
REFERENCE DATA
1. Max. switching power 2. Life curve
1,000 Life, 10 k operations Temperature rise, C 500
3. Coil temperature rise
Sample: ST1-DC24V
60 50 40 30 20 10 0 Contact current 8A 5A 0A
AC resistive load 10 5 Current, A 2 1 DC resistive load 0.5 AC inductive load (cos =0.4)
200 100 50 20
AC 250 V, 125 V resistive load AC 250 V, 125 V inductive load (Pf = 0.4)
0.2 0.1 10 20 50 100 200 300
10 1 2 3 4 5 6 7 8 9 10
0.1
0.2
0.3
0.4
0.5
Voltage, V
Current, A
Coil operating power, W
250
ST
4. Influence of adjacent mounting
Sample: ST1-DC24V
20 Max. temperature, C Rated of change, %
5. Max. ambient temperature by operating power
120 110 100 90 80 70 60 50 40 30 20 10 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Operating power, mW 8 A carrying No load
6. Contact reliability
(%) 99.9 99.8 ST-Relay 99.0 . 250 V AC cos = 1.0 . 95.0 90.0 0.33 Hz 80.0 70.0 60.0 50.0 40.0 250 V AC 25.0 30.0 20.0 15.0 10.0 5.0 4.0 3.0 2.0 8A 10 A 1.5 1.0 m = 3.5 m = 3.9 4 = 16.8x10 = 3.3x105 0.5 0.4 0.3 0.95 = 7.7x104 0.95 = 1.4x105 0.2 0.15 0.1 0.1 0.2 0.3 0.5 0.7 0.9 2.0 3.0 5.07.0 9.0 0.4 0.6 0.8 1.0 No. of operations, x105
10
Drop-out
0 Pick-up -10
(1) (2) (3)
-20 5
(1) & (3) relays are energized. 10 15 20 Inter-relay distance, mm
ST relay socket
Specifications
Breakdown voltage Insulation resistance Heat resistance Max. continuous current Relay insertion life 4,000 Vrms Coil/Contacts 2,000 Vrms Contacts/Contacts More than 1,000 M between terminals 150C (302F) for 1 hr 10 A 15 times
ST-SS Solder terminal socket
ST-PS PC board terminal socket ST-PS
4 .158 16.4 .646 0.3 .012 4.3 .169 0.27 .011 5.5 .217 2.3 .090 7.62 .300 0.3 .012 5.3 .209 0.27 .011 10.16 .400 31.6 1.244 35.4 1.394
7
DIMENSIONS
ST-SS
4 .158 16.4 .646 5.5 .217
mm inch
7.62 .300
10.16 .400 31.6 1.244 35.4 1.394
1.05 .041 7.62 .300
10.16 .400 14.6 .575
10.16 .400 14.6 .575
7.62 .300
8
7
6
5
8
6
5
16.6 .654
1 2 3 4 1 2 3 4
16.6 .654
Precautions for use (socket)
1. PC board mounting method PC board pattern
Contact terminal interval Coil terminal interval
8 7 6 5
15.00.2 .591.008 32.50.1 1.280.004 Press A side Claw for chassis fastening
(2) Insert the relay all the way in, so it is securely in place.
Hinge mechanism
1
2
3
4
2.54 .100 Chassis t = 0.6 to 2.2 .024 to .087
8-1.5 DIA. 8-.060 DIA.
2.54 .100
The terminal configuration is symmetrical on the left and right, so an arrow mark ; is stamped on the socket to prevent misinsertion. We recommend printing the same arrow mark ; on the component mounting side (side opposite from pattern) of the PC board. In this case, the terminal configuration becomes the terminal nos. noted near the drilling holes. 2. Chassis cutout Chassis cutting dimensions
If the chassis hole is punched with a press, set so the release R on the front side (A side). The range for chassis thickness is 0.6 to 2.2 mm .024 to .087 inch . 3. Relay mounting and removal
(1) Align the directions of the relay and socket.
Relay
(3) Press the part indicated by A in the B direction, and fasten by placing the hook on the relay.
Relay case cross-section
B
A
(Before fastening)
(Fastening complete)
(4). When removing the relay, completely release the hooks on both sides and pull the relay out.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000 All Rights Reserved, (c) Copyright Matsushita Electric Works, 251 Ltd.
Go To Online Catalog


▲Up To Search▲   

 
Price & Availability of ST1-DC24V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X